Find the latest bookmaker offers available across all uk gambling sites www.bets.zone Read the reviews and compare sites to quickly discover the perfect account for you.

Oil sampling frequency is one of the most important decision to take in an oil analysis program.

How often to take samples? An appropriate routine would be somewhere between two weeks and three months, and the following recommendations will be generalized to apply to any machine.

The optimal sample frequency for any application should be based on your reliability objectives. First, ask the following questions:

  • How much would it cost my company (in parts, labor and downtime) if the machine suddenly failed?
  • Is there a safety risk associated with a failure?
  • How much would I be willing to invest to forecast the failure 24 hours, one week and one month in advance?

The price you are willing to invest is the theoretical break-even point with all condition monitoring deployed on that machine. Considering that oil analysis may be only one of several condition monitoring strategies deployed and knowing that it is not an absolute solution for predicting failure, you might not invest up to that break-even point. However, some amount less than that would be acceptable.

The next step is to account for the environment, machine failure history, component type, age of the components, etc.

  • How likely is it for the machine’s internal lubrication zones to be exposed to contamination?
  • Has the machine recently been installed or is it approaching its design life?
  • How quickly might a known root cause lead to catastrophic failure?

Predicting a failure with oil analysis is all about having the opportunity to witness the root causes or the symptoms of the failure mode at some point within its failure development period (FDP). The FDP is the time between the failure inception, such as the first time wear debris is produced, to the time functional failure results (complete bearing failure).

Therefore, to lower the remediation costs from an impending failure, you must sample and analyze the oil early within the FDP.

The FDP can be anywhere from a few months to a few hours. Considering that it would be too expensive to sample every hour and of little use to sample outside of a few months, the ideal frequency can be cost-justified somewhere in between and may fluctuate as the risk profile changes.

The questions above should be useful in evaluating the risk profile. They not only can help estimate the machine criticality factor (consequence of failure) but also the failure occurrence factor (the likelihood of failure). When calculating this with a risk matrix, the resulting overall machine criticality can be used to identify the appropriate sampling frequency.

Source: www.machinerylubrication.com

September 19, 2019
oil-sampling-yellow

What is your oil sampling frequency?

Oil sampling frequency is one of the most important decision to take in an oil analysis program. How often to take samples? An appropriate routine would […]
July 31, 2019
skf-grease

7 Steps to Trouble-free Grease Lubrication

It is time to stop treating grease as some simple substance that just needs to be pumped into machines at some random frequency and then hoping […]
July 15, 2019
OilSpill

Oxidation: why good oil turns bad

Oxidation is primary oil degradation mechanism when good oil goes bad. It is the chemical reaction that naturally occurs between the oil and oxygen from the […]
June 4, 2019
IMG_20161201_161140-700x394

Krytox™ Performance Lubricants for the Corrugating Industry

In today’s world of tight margins and intense competition, corrugating operators work hard to squeeze every bit of performance from their machines. That means you need […]